Denso Steelcoat in Riyadh, supplied by Nassguard, provides a protective wrapping system for controlling corrosion under insulation (CUI). Moisture can enter damaged cladding and remain against the pipe beneath the insulation, allowing corrosion to develop out of sight.
The Denso Steelcoat™ CUI Control System places a corrosion-protection barrier directly around the pipe before insulation is installed. Nassguard supplies the system’s materials for suitable projects across Riyadh, Dammam, Jubail, Jeddah and Al Khobar.
Steelcoat CUI Control is a tape-based corrosion-protection system for pipework beneath thermal insulation. Different component arrangements accommodate different service conditions.
The protective layers have low water absorption and low water-vapour transmission characteristics, helping reduce moisture exposure at the metal surface.
Steelcoat CUI Control does not provide thermal insulation. The installation still requires separately specified insulation and weatherproof cladding.
The system offers practical options for protecting pipework during installation and maintenance.
The system suits appropriately specified insulated pipework where moisture-related corrosion requires control.
Before application, assess existing corrosion and establish whether the pipe requires repair or replacement.
Two arrangements form the basis of the Steelcoat CUI Control System.
| Arrangement | Main components | Selection considerations |
|---|---|---|
| System 1 – Elevated-temperature arrangement | Denso Hotline Tape, with Densoseal 16A for specified T-junction profiling | The system literature identifies +30°C to +110°C; confirm the temperature suitability of every component at its location. |
| System 2 – Lower-temperature arrangement | Denso Paste, Densyl Tape, then Denso Clear Outerwrap or Denso PVC Self-Adhesive Tape | Select the outerwrap and confirm the complete assembly’s operating range before purchase. |
Correct installation starts with an assessment of the pipe and a component schedule matched to its duty.
For Riyadh projects, distinguish the pipe’s service temperature from ambient weather conditions and installation temperature.
The following references apply to identified tape-component tests, rather than standalone certification of the complete CUI system.
CUI management requires attention to the complete installation, including the insulation and cladding.
Nassguard supplies materials for CUI-protection enquiries and planned maintenance requirements. Providing clear operating details helps establish the appropriate order.
1. What does CUI mean?
Corrosion under insulation is deterioration of metal beneath insulation, commonly associated with moisture exposure.
2. Does Steelcoat CUI replace thermal insulation?
No, it provides corrosion protection, while thermal insulation remains a separate requirement.
3. Which configuration should I select?
Choose the configuration against the pipe’s operating conditions and the ratings of all selected components.
4. Is abrasive blasting always necessary?
No, but the preparation must meet the requirements of the selected system and substrate condition.
5. What overlap do the primary tapes require?
The CUI system arrangement specifies 55% overlap for Densyl Tape and Denso Hotline Tape.
6. Can the system repair a severely corroded pipe?
No, the pipe’s structural condition must be assessed and any necessary repairs completed before protective wrapping.
7. How can I order Denso Steelcoat in Riyadh?
Contact Nassguard with pipe temperatures, dimensions, treatment lengths, fitting details and delivery requirements.
Denso Steelcoat™ CUI Control System helps protect suitable pipework beneath insulation through a conformable corrosion-resistant wrapping arrangement. Successful selection depends on matching every component to the operating conditions, followed by sound preparation and careful installation.
For Denso Steelcoat in Riyadh, send Nassguard your pipe and insulation specifications. Coordinating the tape, profiling materials and outerwrap before ordering helps ensure the supplied configuration suits the intended work.
| Component property | Specification |
|---|---|
| Densyl Tape construction | Synthetic fabric impregnated and coated with petrolatum compound |
| Densyl Tape typical thickness | 1.15mm |
| Densyl Tape service temperature | −20°C to +70°C |
| Densyl Tape application temperature | −5°C to +55°C |
| Denso Hotline Tape construction | Petrolatum/polymer-impregnated fabric with clear plastic backing |
| Hotline Tape typical thickness | 1.4mm |
| Hotline Tape upper service temperature | +110°C |
| Hotline Tape application temperature | +5°C to +50°C |
| Primary tape roll length | 10m |
| Primary tape widths | 50–300mm |
| PVC Self-Adhesive Tape 200 service temperature | −5°C to +60°C, with a short peak at +80°C |